006 - TS158, For PISCES
Target Project:
PISCES, AR 2.1.5, 2015
Test Instruction : 80143001-TI
Version | Date | Description |
---|---|---|
| Major Updated – TQM-Audit Test Standard
1.1 Subtest 01 : Type A(0cm + 4cm) Subtest 02 : Type B(0cm + 4cm) 1.2 Type B Card, Item Number in Arena = N/A.
2.1 Test Items :Get ATR + APDU Exchange 2.2 ICC Test Card Item Number = 80005206-004 | |
| ||
Rev B - N/A | N/A | N/A |
|
MISC documents
Item | Date | Comment | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VP8800 Key Loading SOP, based on PKI architecture. | |||||||||||||
02 - Firmware : TS Version Table |
|
RE TS158VP8800 - IDPP-1881-U1IDPP-1881D-U1 V1.01.004-C01 Released Specific QC Mode wo MSR..msg
| ||||||||||||
03 - Specific Part Numbers , United AirlineIDPP-1881D-U1:IDPP-1881-U1: |
| <USDK-PKI, Demo><Client Certs> United Airline certificates loading process. 1.Device Signing and IDTech Certs 2.SMFG Load Client Certs (from CA Server) 3.Allowed Demo S/N Range : 880Z000001~880Z000020 |
Download Link
Version | Date | Comment | Verified FW, Software, SQ |
---|---|---|---|
V 1.01.010 | |||
| V1.01.010-C01 . 2020 Feb 19, goofy_liu, ==[DUT]=== | ||
V 1.01.009 | |||
| 1.Legacy P/N Updated, QC-US mode has been added. IDPP-1881D : | ||
V 1.01.008 | |||
| SQA Test JIRA : TE-437 | ||
| 1.Touch Panel Issue Fixed. Root: Complex drawing signature needs more time & buffer size Resolution: 1.A Signing Timeout up to 60 seconds. 1.B Add-up Receiving Buffer size to 20K Developer Note: More Buffer size(~20k = ClassDevRS232.m_cnRX_BUF_MAX), USB-HID dll max buf size check SQA Test JIRA : TE-437 | ||
|
Visa-TQM Audit Issue - RFID Test. old : 0cm+4cm && CL Type A , 2-subTest required. new : 0cm+4cm && CL Type A+B , 4-subTest required. | ||
|
(+) IDPP-1880D-M1: (Demo Version) a.Secure Keys Checking Rules QC-Mode : PKI KEK, PIN Key, Data Key(DEK) QCUS-Mode : PKI KEK, PIN Key, Data Key(DEK) | ||
|
(+) IDPP-1880-M1: a.Secure Keys Checking Rules QC-Mode : PKI KEK, PIN Key QCUS-Mode : PKI KEK, PIN Key, Data Key(DEK)
-------- Note01: Requested e-mail - RE Please Help To Resign_VP8800.msg | ||
|
========================================= V1.01.007-C01 . 2019 Feb 21, goofy_liu,
| ||
V 1.01.006 | |||
| 1.Added Device Reset Failed Check (90-07+90-00) before Tamper Enable(90-02) @ Tamper Check Item. | ||
| ---<Firmware Image Information>--- ===========================
===========================
OS, Linux, v3.14.58
[M] IDPP-1881D-U1; IDPP-1881-U1; Objective: MSR Test @ QC Mode is now available since IDG Command 2C-20 Swipe MSR is ready.
old: D1-16 new: 90-14 (ONLY available in UMFG mode)
(a) Settings, Production + QC modes. | ||
V 1.01.005 | |||
|
IDPP-1381 : RS232. IDPP-1381D : RS232. IDPP-1581 : USB-HID. IDPP-1581D : USB-HID.
[Note] Please use Firmware Version D_U1_r25259, IDPP-1881D-U1, No MSR Test @ QC mode since r25259 w/o 2C-20 SMFG mode Support. IDPP-1881-U1, No MSR Test @ QC mode since r25259 w/o 2C-20 SMFG mode Support. | ||
| V1.01.005-C01 .D_U1_r25259, 2019 Feb 23, goofy_liu, 1.P/N List Updated Updated ALL P/Ns' Production Tests w/ Full Test Items from this version since Battery Absense Issue can't be detected by Firmware and No Repower On behavior in certain part number (specially for -U1 Part Number). 2.Tamper Test Scenario @ Production Mode. Adding Re-power ON step to prevent from RTC/Battery Absence Issue. | ||
V 1.01.004 | |||
| V1.01.004-C01 .D_U1_r25259, 2019 Jan 31, goofy_liu,
P/N List Updated. Temporarily Removed QC Mode MSR Test @ IDPP-1881D-U1. @ IDPP-1881-U1.
If NOT allowed, then [Exit] Directly !! | ||
V 1.01.003 | |||
|
| ||
| |||
|
| ||
V 1.01.002 | |||
|
+IDPP-1881D-U1
IDPP-1381D = IDPP-1581D = IDPP-1881D = IDPP-1881D-U1 = LCL-KEK(14)+Data Encrytion Key(02)+PIN Key(01) IDPP-1381 = IDPP-1581 = IDPP-1881 = IDPP-1881-U1 = LCL-KEK(14)
Error: Kate reported V1.01.001-C01 has limited ONLY to Build:25269 Correct: To all FW builds. | ||
V 1.01.001 | |||
|
FW Build: 25269 or later version. | ||
V 1.00.009 | |||
|
Smart Check Injected Keys.
This function will be supported 2C-20 cmd for MSR Test . QC mode (Activated,Keys Installation) in next release w/ Firmware Build 25269. | ||
|
Using 90-02 w/o S/N --> Work in Tamper Test Scenario.
| ||
V 1.00.008 | |||
|
Update Tamper Repower-On Message to ask user/operator to press [OK] after UUT beeps and being in Ready Status. | ||
|
| ||
| Approved in Build FW: 25252, Demo Version
Test Card: TRACK 1 = %TRACK17676760707077676760707077676760707077676760707077676760707077676760707?C TRACK 2 = ;2121212121767676070707767676762121212?0 TRACK 3 = ;33333333337676760707077676763333333333767676070707767676333333333376767607070776767633333333337676760707?2 ~~~~~~ Q-Card: TRACK 1 = %0123456789012345678901234567890123456789012345678901234567890123456789012345?: TRACK 2 = ;0123456789012345678901234567890123456?2 TRACK 3 = ;01234567890123456789012345678901234567890123456789012345678901234567890123456789012345678901234567890123?4
old: TS158_PISCES_NoExt.exe new: TS158_VP8800_NoExt.exe
= MSR Test Available since Data Key Exists = MSR Test N/A since No Data Key Exists Production P/N - MSR item at QC mode ------------------------------------------------------------ IDPP-1381 - MSR IDPP-1581 - MSR IDPP-1881 - MSR IDPP-1881-U1 - MSR IDPP-1X81X - MSR Demo P/N - MSR item at QC mode ------------------------------------------------------------ IDPP-1381D - MSR IDPP-1581D - MSR IDPP-1881D - MSR | ||
V 1.00.007 | |||
|
a.Remove RS232 Item @ IDPP-1881-U1 b.Add United Cert Check "0F" @ IDPP-1881-U1, QC Mode c.Remove Key Checks: PIN Key; DUKPT (Data) Key; d.Remove MSR @ QC mode, since only LCL-KEK, w/o DUKPT & PIN | ||
| verified w/ FW build:25041~ 1.Ethernet Ping - Add Netmask 255.255.255.0 2.Update P/N Replace half size "-" with full size "-". | ||
| verified w/ FW build:25016
Add Device Reset in MSR; RFID; ICC since Tamper Test might stay in Tamper Eanble status (Generation CSR) to produce MSR Act Txn Error w/ returning sts 0x0A immediately.
Update Tamper Eanble / Disable Command Group old: 04-21 + 01 / 04-21 + 03 new: 90-07;90-00;90-02 / 90-07;90-00
Add LCD Cust Display Mode ON --> Show Default Image --> Cust Mode OFF to display LCD Test Patterns.
| ||
| verified w/ FW build:25016
for Tamper-Battery test.
They are LCL-KEK, DUKPT Key, and PIN Key.
a) RS232 b) USB-HID c) USB-HID+ ETH d) RS232+ USB-HID+ ETH
Wire 1 <--> 0 message displays reversed. Printing out detail info when Engineer Mode w/ Debug "ON". |
RE Tamper verification for NEO 2 and VP8800 - TS improvement schedule..msg | |
V 1.00.006 | |||
| 1.Date/Time Test : Time Zone Update old = GMT/UTC + 08:00 new = GMT/UTC + 00:00 since NEO 2.0 Certificates Injection Tool sets UTC +00:00 as standard time in the reader. Old Time zone may cause Time Check Error in QC mode. | ||
V 1.00.005 | |||
| 1.Tamper Item Update a.Add Tamper Enable / Disable Functions before and after "Get Tamper Status". b.Fixed Incorrect Tamper Info. | ||
| 1.Remove Board Level Test Icon (BTM-XX..) 2.Add Delay 500m between MSR Test and RFID one. To provide more restoration time of 02-05 command after 1st time Erase Flash. 3.Update FW Info display message Old: "..TM4.." New: "NEO 2.0 / AR 3.0.0 +..." 4.Update Part Number List. 5.Verified @ FW V24089 | ||
| V1.00.005-C01, 2018 Jan 11 Released
a-removed test items a.1-MSR test, KSN issue b-Tamper Test Update - Remove Tamper Enable while in QC mode c.USB-HID Test Update
Legacy: 02-20 (Interface selectable, Non-secured) New: 02-05 (Interface selectable, Secured/Non-secured compatible)
Legacy 25-05 New,UMFG mode, 90-07 --> 90-00 --> 90-01
UMFG / SMFG Features Support a.Load Certificates Support @ Engineer Mode b.Load Keys Function Support @ Engineer Mode c.QC Mode, item name update: Legacy,Err "G53 MCD Chk" --> Ok "G53 MCU Chk"
M IDPP-1X81 --> IDPP-1X81X + IDPP-1381.D RS232 (115200), No USB-HID, No Ethernet + IDPP-1581.D, No RS232, USB-HID, No Ethernet, SRED + IDPP-1881.D, No RS232, USB-HID, Ethernet, SRED | Verified with FW V.24793 | |
V 1.00.004 | |||
1.Part Number List Update +) IDPP-1381, RS232 (115200), No USB-HID, No Ethernet +) IDPP-1581, No RS232, USB-HID, No Ethernet +) IDPP-1881, No RS232, USB-HID, Ethernet +) IDPP-1X81, RS232, USB-HID, Ethernet -) IDPP-1XX, the legacy one. 2.Rename USB_HID_IDTW.dll to USB_HID_IDTW_32bit.dll | |||
V 1.00.003 | |||
V1.00.003-C03 |
| ========================================= V1.00.003-C03, 2017 Mar 21 Released 1.Tamper more check and user confirm, since Tamper Enable behavior ONLY has ONE Chance 2.Remove Tamper Enable in RTC/Date & Time Set 3.Remove 09-14 in AR Platform in Connection ========================================= V1.00.003-C02, 2017 Feb 23 Released 1.Eng Mode - Add Enter Bootloader Mode. 2.[Time Check]Remove Tamper Enable Cmd before Time Check Cmds Performing, in Time Check Item. 3.[LCD Pixels] Combined 3 kinds of LCD Test Sub Items into one. Each display has 800 ms interval time to next one. Old: ON, Click [PASS] --> OFF, Click [PASS] --> Color Bars, Click [PASS] New: ON->OFF->Color Bars->Again (10 secs period) , Click [PASS] 4.[Ethernet] Set After Test. Old: Ethernet MAC Injection --> Ethernet Ping Check New: Ethernet Ping Check --> Ethernet MAC Injection 5.[Start All Test][Run As Administrator] Add 1st round notification regarding "Run As Administrator". 6.[Keypad test] - Add Cust Disp ON --> OFF to avoid Keypad no response problem. | FW:23558 |
V1.00.003-C01 | 1.RTC Timer Set / Get = 25-05 / 25-06 2.Add Ethernet MAC Address Injection / Check Item 3.[UI,Form04] Adjust Test Item Buttons Maxtrix Area sizing to all buttons view range. 4.Keypad Test Item Update | SW = r23240 SQA = ? | |
V 1.00.002 | |||
V1.00.002-C03Internal Test | V1.00.002-C03, 2016 Dec 14 Released 1.Add "Administrator Privilege" in manifest.xml definition. | ||
V1.00.002-C02Internal Test | V1.00.002-C02, 2016 Dec 13 Released 1.Modified LED Display Message | ||
V1.00.002-C01Internal Test | V1.00.002-C01, 2016 Dec 08 Released --< Mod >-- 1.Network Ethernet Interface Setting Cmd D1-13 Tx/Rx Format Updated 2.[Eng Mode], Some Test Buttons are not cleared after disconnection. 3.KeyPad Test - Cancel Function Ready but still takes time to end (1~4 secs). Timeout Value Per Pressing Delay , 50 secs --> 4 secs. 4.Formal Part Number Added +IDPP – 138 | ||
*V1.00.001-C03, HWOnly | 2016 Nov 08 V1.00.001-C03 HW Test Tool | ||
V 1.00.001 | |||
*V 1.00.001-C03Formal Release | V1.00.001-C03 Formal Release for .. 1.Board Level Test 2.Production Test 3.QC Mode Test | ||
V1.00.001-C01 | V1.00.001-C01 PISCES, Beta 1 Version | ||
V 0.00.0XX | |||
V 0.00.006-C01 | TS158, V0.00.006-C01 PISCES, Beta 1 Version | ||
SetupTS158_0.00.005-C10.exe | V0.00.005-C10, 2016 Sept 07 Released 1.Mod - Tamper Test, Replace messages "Can't Get Tamper Status" with "Get Tampers Done with OK, All OFF"
| ||
SetupTS158_0.00.005-C09.exe | V0.00.005-C09 Released, Sept 06 1.Tamper Test Forever Loop Bugs 2.Tamper Value Display | ||
SetupTS158_0.00.005-C08.exe | V0.00.005-C08 Released, Sept 05 1.Message Changed. Tamper 2,3 --> Wire 0,1 | ||
SetupTS158_0.00.005-C07.exe | V0.00.005-C07 Released, Sept 02 1.Modified Tamper Get Status Value. 2.De-activate RFID Interface After Poll For Token. | ||
SetupTS158_0.00.005-C06.exe | V0.00.005-C06 Released 1.Touch - Signature Simplification | ||
SetupTS158_0.00.005-C04.exe | ---<005-C04>--- | ||
SetupTS158_0.00.005-C02.exe | ---<005-C02>--- | ||
SetupTS158_0.00.005.exe | ---<005-C01>--- | ||
SetupTS158_0.00.004.exe | ---<C004>--- | ||
SetupTS158_0.00.003.exe | ---<C003>--- | ||
SetupTS158_0.00.002.exe | ---<C002>--- | ||
SetupTS158_0.00.001.exe | ---<C001>--- |
Target Project:
PISCES, AR 2.1.5, 2015
Test Instruction : 80143001-TI
Version | Date | Description |
---|---|---|
| ||
Rev B - N/A | N/A | N/A |
|
MISC documents
Item | Date | Comment | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VP8800 Key Loading SOP, based on PKI architecture. | |||||||||||||
02 - Firmware : TS Version Table |
|
RE TS158VP8800 - IDPP-1881-U1IDPP-1881D-U1 V1.01.004-C01 Released Specific QC Mode wo MSR..msg
|
Download Link
Version | Date | Comment | Verified FW, Software, SQ |
---|---|---|---|
V 1.01.008 | |||
|
(+) IDPP-1880D-M1: (Demo Version) a.Secure Keys Checking Rules QC-Mode : LCL-KEK, PIN Key, Data Key(DEK) QCUS-Mode : LCL-KEK, PIN Key, Data Key(DEK)
old : 0cm+4cm && CL Type A , 2-subTest required. new : 0cm+4cm && CL Type A+B , 4-subTest required. SQA Approval JIRA: - TE-437Getting issue details... STATUS | ||
|
(+) IDPP-1880-M1: a.Secure Keys Checking Rules QC-Mode : LCL-KEK, PIN Key QCUS-Mode : LCL-KEK, PIN Key, Data Key(DEK) -------- Note01: Requested e-mail - RE Please Help To Resign_VP8800.msg | ||
|
========================================= V1.01.007-C01 . 2019 Feb 21, goofy_liu,
| ||
V 1.01.006 | |||
| 1.Added Device Reset Failed Check (90-07+90-00) before Tamper Enable(90-02) @ Tamper Check Item. | ||
| ---<Firmware Image Information>--- ===========================
===========================
OS, Linux, v3.14.58
[M] IDPP-1881D-U1; IDPP-1881-U1; Objective: MSR Test @ QC Mode is now available since IDG Command 2C-20 Swipe MSR is ready.
old: D1-16 new: 90-14 (ONLY available in UMFG mode)
(a) Settings, Production + QC modes. | ||
V 1.01.005 | |||
|
IDPP-1381 : RS232. IDPP-1381D : RS232. IDPP-1581 : USB-HID. IDPP-1581D : USB-HID.
[Note] Please use Firmware Version D_U1_r25259, IDPP-1881D-U1, No MSR Test @ QC mode since r25259 w/o 2C-20 SMFG mode Support. IDPP-1881-U1, No MSR Test @ QC mode since r25259 w/o 2C-20 SMFG mode Support. | ||
| V1.01.005-C01 .D_U1_r25259, 2019 Feb 23, goofy_liu, 1.P/N List Updated Updated ALL P/Ns' Production Tests w/ Full Test Items from this version since Battery Absense Issue can't be detected by Firmware and No Repower On behavior in certain part number (specially for -U1 Part Number). 2.Tamper Test Scenario @ Production Mode. Adding Re-power ON step to prevent from RTC/Battery Absence Issue. | ||
V 1.01.004 | |||
| V1.01.004-C01 .D_U1_r25259, 2019 Jan 31, goofy_liu,
P/N List Updated. Temporarily Removed QC Mode MSR Test @ IDPP-1881D-U1. @ IDPP-1881-U1.
If NOT allowed, then [Exit] Directly !! | ||
V 1.01.003 | |||
|
| ||
| |||
|
| ||
V 1.01.002 | |||
|
+IDPP-1881D-U1
IDPP-1381D = IDPP-1581D = IDPP-1881D = IDPP-1881D-U1 = LCL-KEK(14)+Data Encrytion Key(02)+PIN Key(01) IDPP-1381 = IDPP-1581 = IDPP-1881 = IDPP-1881-U1 = LCL-KEK(14)
Error: Kate reported V1.01.001-C01 has limited ONLY to Build:25269 Correct: To all FW builds. | ||
V 1.01.001 | |||
|
FW Build: 25269 or later version. | ||
V 1.00.009 | |||
|
Smart Check Injected Keys.
This function will be supported 2C-20 cmd for MSR Test . QC mode (Activated,Keys Installation) in next release w/ Firmware Build 25269. | ||
|
Using 90-02 w/o S/N --> Work in Tamper Test Scenario.
| ||
V 1.00.008 | |||
|
Update Tamper Repower-On Message to ask user/operator to press [OK] after UUT beeps and being in Ready Status. | ||
|
| ||
| Approved in Build FW: 25252, Demo Version
Test Card: TRACK 1 = %TRACK17676760707077676760707077676760707077676760707077676760707077676760707?C TRACK 2 = ;2121212121767676070707767676762121212?0 TRACK 3 = ;33333333337676760707077676763333333333767676070707767676333333333376767607070776767633333333337676760707?2 ~~~~~~ Q-Card: TRACK 1 = %0123456789012345678901234567890123456789012345678901234567890123456789012345?: TRACK 2 = ;0123456789012345678901234567890123456?2 TRACK 3 = ;01234567890123456789012345678901234567890123456789012345678901234567890123456789012345678901234567890123?4
old: TS158_PISCES_NoExt.exe new: TS158_VP8800_NoExt.exe
= MSR Test Available since Data Key Exists = MSR Test N/A since No Data Key Exists Production P/N - MSR item at QC mode ------------------------------------------------------------ IDPP-1381 - MSR IDPP-1581 - MSR IDPP-1881 - MSR IDPP-1881-U1 - MSR IDPP-1X81X - MSR Demo P/N - MSR item at QC mode ------------------------------------------------------------ IDPP-1381D - MSR IDPP-1581D - MSR IDPP-1881D - MSR | ||
V 1.00.007 | |||
|
a.Remove RS232 Item @ IDPP-1881-U1 b.Add United Cert Check "0F" @ IDPP-1881-U1, QC Mode c.Remove Key Checks: PIN Key; DUKPT (Data) Key; d.Remove MSR @ QC mode, since only LCL-KEK, w/o DUKPT & PIN | ||
| verified w/ FW build:25041~ 1.Ethernet Ping - Add Netmask 255.255.255.0 2.Update P/N Replace half size "-" with full size "-". | ||
| verified w/ FW build:25016
Add Device Reset in MSR; RFID; ICC since Tamper Test might stay in Tamper Eanble status (Generation CSR) to produce MSR Act Txn Error w/ returning sts 0x0A immediately.
Update Tamper Eanble / Disable Command Group old: 04-21 + 01 / 04-21 + 03 new: 90-07;90-00;90-02 / 90-07;90-00
Add LCD Cust Display Mode ON --> Show Default Image --> Cust Mode OFF to display LCD Test Patterns.
| ||
| verified w/ FW build:25016
for Tamper-Battery test.
They are LCL-KEK, DUKPT Key, and PIN Key.
a) RS232 b) USB-HID c) USB-HID+ ETH d) RS232+ USB-HID+ ETH
Wire 1 <--> 0 message displays reversed. Printing out detail info when Engineer Mode w/ Debug "ON". |
RE Tamper verification for NEO 2 and VP8800 - TS improvement schedule..msg | |
V 1.00.006 | |||
| 1.Date/Time Test : Time Zone Update old = GMT/UTC + 08:00 new = GMT/UTC + 00:00 since NEO 2.0 Certificates Injection Tool sets UTC +00:00 as standard time in the reader. Old Time zone may cause Time Check Error in QC mode. | ||
V 1.00.005 | |||
| 1.Tamper Item Update a.Add Tamper Enable / Disable Functions before and after "Get Tamper Status". b.Fixed Incorrect Tamper Info. | ||
| 1.Remove Board Level Test Icon (BTM-XX..) 2.Add Delay 500m between MSR Test and RFID one. To provide more restoration time of 02-05 command after 1st time Erase Flash. 3.Update FW Info display message Old: "..TM4.." New: "NEO 2.0 / AR 3.0.0 +..." 4.Update Part Number List. 5.Verified @ FW V24089 | ||
| V1.00.005-C01, 2018 Jan 11 Released
a-removed test items a.1-MSR test, KSN issue b-Tamper Test Update - Remove Tamper Enable while in QC mode c.USB-HID Test Update
Legacy: 02-20 (Interface selectable, Non-secured) New: 02-05 (Interface selectable, Secured/Non-secured compatible)
Legacy 25-05 New,UMFG mode, 90-07 --> 90-00 --> 90-01
UMFG / SMFG Features Support a.Load Certificates Support @ Engineer Mode b.Load Keys Function Support @ Engineer Mode c.QC Mode, item name update: Legacy,Err "G53 MCD Chk" --> Ok "G53 MCU Chk"
M IDPP-1X81 --> IDPP-1X81X + IDPP-1381.D RS232 (115200), No USB-HID, No Ethernet + IDPP-1581.D, No RS232, USB-HID, No Ethernet, SRED + IDPP-1881.D, No RS232, USB-HID, Ethernet, SRED | Verified with FW V.24793 | |
V 1.00.004 | |||
1.Part Number List Update +) IDPP-1381, RS232 (115200), No USB-HID, No Ethernet +) IDPP-1581, No RS232, USB-HID, No Ethernet +) IDPP-1881, No RS232, USB-HID, Ethernet +) IDPP-1X81, RS232, USB-HID, Ethernet -) IDPP-1XX, the legacy one. 2.Rename USB_HID_IDTW.dll to USB_HID_IDTW_32bit.dll | |||
V 1.00.003 | |||
V1.00.003-C03 |
| ========================================= V1.00.003-C03, 2017 Mar 21 Released 1.Tamper more check and user confirm, since Tamper Enable behavior ONLY has ONE Chance 2.Remove Tamper Enable in RTC/Date & Time Set 3.Remove 09-14 in AR Platform in Connection ========================================= V1.00.003-C02, 2017 Feb 23 Released 1.Eng Mode - Add Enter Bootloader Mode. 2.[Time Check]Remove Tamper Enable Cmd before Time Check Cmds Performing, in Time Check Item. 3.[LCD Pixels] Combined 3 kinds of LCD Test Sub Items into one. Each display has 800 ms interval time to next one. Old: ON, Click [PASS] --> OFF, Click [PASS] --> Color Bars, Click [PASS] New: ON->OFF->Color Bars->Again (10 secs period) , Click [PASS] 4.[Ethernet] Set After Test. Old: Ethernet MAC Injection --> Ethernet Ping Check New: Ethernet Ping Check --> Ethernet MAC Injection 5.[Start All Test][Run As Administrator] Add 1st round notification regarding "Run As Administrator". 6.[Keypad test] - Add Cust Disp ON --> OFF to avoid Keypad no response problem. | FW:23558 |
V1.00.003-C01 | 1.RTC Timer Set / Get = 25-05 / 25-06 2.Add Ethernet MAC Address Injection / Check Item 3.[UI,Form04] Adjust Test Item Buttons Maxtrix Area sizing to all buttons view range. 4.Keypad Test Item Update | SW = r23240 SQA = ? | |
V 1.00.002 | |||
V1.00.002-C03Internal Test | V1.00.002-C03, 2016 Dec 14 Released 1.Add "Administrator Privilege" in manifest.xml definition. | ||
V1.00.002-C02Internal Test | V1.00.002-C02, 2016 Dec 13 Released 1.Modified LED Display Message | ||
V1.00.002-C01Internal Test | V1.00.002-C01, 2016 Dec 08 Released --< Mod >-- 1.Network Ethernet Interface Setting Cmd D1-13 Tx/Rx Format Updated 2.[Eng Mode], Some Test Buttons are not cleared after disconnection. 3.KeyPad Test - Cancel Function Ready but still takes time to end (1~4 secs). Timeout Value Per Pressing Delay , 50 secs --> 4 secs. 4.Formal Part Number Added +IDPP – 138 | ||
*V1.00.001-C03, HWOnly | 2016 Nov 08 V1.00.001-C03 HW Test Tool | ||
V 1.00.001 | |||
*V 1.00.001-C03Formal Release | V1.00.001-C03 Formal Release for .. 1.Board Level Test 2.Production Test 3.QC Mode Test | ||
V1.00.001-C01 | V1.00.001-C01 PISCES, Beta 1 Version | ||
V 0.00.0XX | |||
V 0.00.006-C01 | TS158, V0.00.006-C01 PISCES, Beta 1 Version | ||
SetupTS158_0.00.005-C10.exe | V0.00.005-C10, 2016 Sept 07 Released 1.Mod - Tamper Test, Replace messages "Can't Get Tamper Status" with "Get Tampers Done with OK, All OFF"
| ||
SetupTS158_0.00.005-C09.exe | V0.00.005-C09 Released, Sept 06 1.Tamper Test Forever Loop Bugs 2.Tamper Value Display | ||
SetupTS158_0.00.005-C08.exe | V0.00.005-C08 Released, Sept 05 1.Message Changed. Tamper 2,3 --> Wire 0,1 | ||
SetupTS158_0.00.005-C07.exe | V0.00.005-C07 Released, Sept 02 1.Modified Tamper Get Status Value. 2.De-activate RFID Interface After Poll For Token. | ||
SetupTS158_0.00.005-C06.exe | V0.00.005-C06 Released 1.Touch - Signature Simplification | ||
SetupTS158_0.00.005-C04.exe | ---<005-C04>--- | ||
SetupTS158_0.00.005-C02.exe | ---<005-C02>--- | ||
SetupTS158_0.00.005.exe | ---<005-C01>--- | ||
SetupTS158_0.00.004.exe | ---<C004>--- | ||
SetupTS158_0.00.003.exe | ---<C003>--- | ||
SetupTS158_0.00.002.exe | ---<C002>--- | ||
SetupTS158_0.00.001.exe | ---<C001>--- |