Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 76 Next »


Target Project:

PISCES, AR 2.1.5, 2015


Test Instruction

VersionDescription

Initial Release

2017 Nov 10

Presented by goofy.liu




MISC documents

ItemComment

 

VP8800 Key Loading SOP, based on PKI architecture.






Download Link

VersionDateCommentVerified FW, Software, SQ

V 1.01.006




 



V 1.01.005




 

 goofy.liu

  • 1. Removed/OBS PNs

IDPP-1381    : RS232.

IDPP-1381D   : RS232.

IDPP-1581    : USB-HID.
IDPP-1581D   :  USB-HID.   
  • 2. Customized Part Numbers w/ Specific Firmware Version

[Note] Please use Firmware Version D_U1_r25259,

  IDPP-1881D-U1, No MSR Test @ QC mode since r25259 w/o 2C-20 SMFG mode Support.

  IDPP-1881-U1, No MSR Test @ QC mode since r25259 w/o 2C-20 SMFG mode Support.

 

 goofy.liu

V1.01.005-C01 .D_U1_r25259, 2019 Feb 23, goofy_liu,


1.P/N List Updated

Updated ALL P/Ns' Production Tests w/ Full Test Items from this version

since Battery Absense Issue can't be detected by Firmware and No Repower On behavior in certain part number (specially for -U1 Part Number).

2.Tamper Test Scenario  @ Production Mode.

  Adding Re-power ON step to prevent from RTC/Battery Absence Issue.

V 1.01.004




 

 goofy.liu

V1.01.004-C01 .D_U1_r25259, 2019 Jan 31, goofy_liu,

  • 1.For FW Build:25259 DA Version

P/N List Updated.

Temporarily Removed QC Mode MSR Test

  @ IDPP-1881D-U1.

  @ IDPP-1881-U1.

  • 2.+ File Info Version = ReleaseNote.txt the latest version validation check.

If NOT allowed, then [Exit] Directly !!


V 1.01.003




 

 goofy.liu

  • 1.Fixed RS232 Test if useing IDPP-1X81 + USB-HID connection.

 

 goofy.liu

  • 1.Update Tamper Test.

 + USB Connection check prior to Tamper test start.


 

 goofy.liu

  • 1.Update Tamper Test.

V 1.01.002




 

 goofy.liu

  • 1.Part Number List Update

+IDPP-1881D-U1

  • 2.QC Mode Secure Info - Injection Keys Check Rule Update

IDPP-1381D =  IDPP-1581D = IDPP-1881D = IDPP-1881D-U1 = LCL-KEK(14)+Data Encrytion Key(02)+PIN Key(01)

IDPP-1381  =  IDPP-1581  = IDPP-1881  = IDPP-1881-U1  = LCL-KEK(14)

  • 3.Support MSR Test Command 2C-20 to All FW Verison.

Error: Kate reported V1.01.001-C01 has limited ONLY to Build:25269

Correct: To all FW builds.


V 1.01.001




 

 goofy.liu

  • 1.[QC mode] support 2C-20 MSR Test , don't care key status.

FW Build: 25269 or later version.

V 1.00.009




 

 goofy.liu

  • 1.Update Keys & Certificate Check method @ QC mode.

 Smart Check Injected Keys.

  • 2.No MSR Test in QC mode.

This function will be supported 2C-20 cmd for MSR Test .

QC mode (Activated,Keys Installation) in next release w/ Firmware Build 25269.


 

 goofy.liu

  • 1.Update Tamper Check Scenario, Remove Repower-On UUT

Using 90-02 w/o S/N --> Work in Tamper Test Scenario.

  • 2.USB-HID test, + Repower-On UUT.
  • 3.Perform S/N Injection after All Test Items.

V 1.00.008




 

 goofy.liu

  • 1.[Exclusive in IDPP-1381,IDPP-1381D]

Update Tamper Repower-On Message to ask

user/operator to press [OK] after UUT beeps and being in Ready Status.


 

 goofy.liu

  • 1.Fixed S/N input issue.

 

 goofy.liu

Approved in Build FW: 25252, Demo Version

  • 1.Verified New MSR Format, w/ LRC

Test Card:

TRACK 1 = %TRACK17676760707077676760707077676760707077676760707077676760707077676760707?C

TRACK 2 = ;2121212121767676070707767676762121212?0

TRACK 3 = ;33333333337676760707077676763333333333767676070707767676333333333376767607070776767633333333337676760707?2

~~~~~~

Q-Card:

TRACK 1 = %0123456789012345678901234567890123456789012345678901234567890123456789012345?:

TRACK 2 = ;0123456789012345678901234567890123456?2

TRACK 3 = ;01234567890123456789012345678901234567890123456789012345678901234567890123456789012345678901234567890123?4


  • 2.Isolated Secure Info Item @ QC mode
  • 3.Isolated Customized Config Item @ Production + QC mode.
  • 4.Rename exe file

old: TS158_PISCES_NoExt.exe

new: TS158_VP8800_NoExt.exe

  • 5. P/N configuration Update for MSR Test at QC mode.

(加号) = MSR Test Available since Data Key Exists

(减号) = MSR Test N/A since No Data Key Exists

Production P/N             - MSR item at QC mode

------------------------------------------------------------

IDPP-1381                   - (减号) MSR

IDPP-1581                   - (减号) MSR

IDPP-1881                   - (减号) MSR

IDPP-1881-U1               - (减号) MSR

IDPP-1X81X                  - (加号) MSR


Demo P/N             - MSR item at QC mode

------------------------------------------------------------

IDPP-1381D                  - (加号) MSR

IDPP-1581D                  - (加号) MSR

IDPP-1881D                  - (加号) MSR


V 1.00.007




 

 goofy.liu

  • 1.Update Items for IDPP-1881-U1, Customer : United Air Line

a.Remove RS232 Item @ IDPP-1881-U1

b.Add United Cert Check "0F" @ IDPP-1881-U1, QC Mode

c.Remove Key Checks: PIN Key; DUKPT (Data) Key;

d.Remove MSR @ QC mode, since only LCL-KEK, w/o DUKPT & PIN


 

 goofy.liu

verified w/ FW build:25041~

1.Ethernet Ping - Add Netmask 255.255.255.0

2.Update P/N

Replace half size "-" with full size "-".


 

 goofy.liu

verified w/ FW build:25016

  • 1.Production Mode, Device Reset

Add Device Reset in MSR; RFID; ICC

since Tamper Test might stay in Tamper Eanble status

(Generation CSR) to produce MSR Act Txn Error w/ returning sts 0x0A immediately.

  • 2.Tamper Test:

Update Tamper Eanble / Disable Command Group

old: 04-21 + 01 / 04-21 + 03

new: 90-07;90-00;90-02 / 90-07;90-00

  • 3.QC Mode, LCD Test.

Add LCD Cust Display Mode ON --> Show Default Image --> Cust Mode OFF

to display LCD Test Patterns.

  • 4.Add UMFG-SN before Tamper Test. Copied from NEO 2.0 test plan.
  • 5.P/N Update

    + IDPP-1881-U1, RS232 + USB-HID + Ethernet


 

 goofy.liu

verified w/ FW build:25016

  • 1.+MSR, LEDs+Buzzer, and LCD Tests in QC mode.
  • 2.Re-power UUT after Tamper Enable(90-02),

for Tamper-Battery test.

  • 3.Secured Keys Check Rule in All P/Ns.

  They are LCL-KEK, DUKPT Key, and PIN Key.

  • 4.P/N Check Rules Update

a) RS232

b) USB-HID

c) USB-HID+ ETH

d) RS232+ USB-HID+ ETH

  • 5.Add Get Certs (81-0E) Info Check @ FW Info QC mode.
  • 6.[Fixed] 2018 Feb 02, HW Tony's Report.

Wire 1 <--> 0 message displays reversed.

Printing out detail info when Engineer Mode w/ Debug "ON".

V 1.00.006




 

 goofy.liu

1.Date/Time Test : Time Zone Update

old = GMT/UTC + 08:00

new = GMT/UTC + 00:00

since NEO 2.0 Certificates Injection Tool

sets UTC +00:00 as standard time in the reader.

Old Time zone may cause Time Check Error in QC mode.


V 1.00.005




 

 goofy.liu

1.Tamper Item Update

 a.Add Tamper Enable / Disable Functions before and after "Get Tamper Status".

 b.Fixed Incorrect Tamper Info.


 

 goofy.liu

1.Remove Board Level Test Icon (BTM-XX..)

2.Add Delay 500m between MSR Test and RFID one.

  To provide more restoration time of 02-05 command

  after 1st time Erase Flash.

3.Update FW Info display message

  Old: "..TM4.."

  New: "NEO 2.0 / AR 3.0.0 +..."

4.Update Part Number List.

5.Verified @ FW V24089


 

  goofy.liu

V1.00.005-C01, 2018 Jan 11 Released

  • 1.QC mode, PCI enable

  a-removed test items

    a.1-MSR test, KSN issue

  b-Tamper Test Update -

    Remove Tamper Enable while in QC mode

  c.USB-HID Test Update

  • 2.MSR test item.

Legacy: 02-20 (Interface selectable, Non-secured)

New:    02-05 (Interface selectable, Secured/Non-secured compatible)

  • 3.RTC, Data/Time Set commands

Legacy 25-05

New,UMFG mode, 90-07 --> 90-00 --> 90-01

  • 4.Engineer Mode,

UMFG / SMFG Features Support

a.Load Certificates Support @ Engineer Mode

b.Load Keys Function Support @ Engineer Mode

c.QC Mode, item name update:

Legacy,Err "G53 MCD Chk" -->

Ok "G53 MCU Chk"

  • 5.Part Number List Update

M IDPP-1X81 --> IDPP-1X81X

+ IDPP-1381.D  RS232 (115200), No USB-HID, No Ethernet

+ IDPP-1581.D, No RS232, USB-HID, No Ethernet, SRED

+ IDPP-1881.D, No RS232, USB-HID, Ethernet, SRED

Verified with FW V.24793

V 1.00.004





1.Part Number List Update

+) IDPP-1381, RS232 (115200), No USB-HID, No Ethernet

+) IDPP-1581, No RS232, USB-HID, No Ethernet

+) IDPP-1881, No RS232, USB-HID, Ethernet

+) IDPP-1X81, RS232, USB-HID, Ethernet

-) IDPP-1XX, the legacy one.


2.Rename USB_HID_IDTW.dll to USB_HID_IDTW_32bit.dll


V 1.00.003




V1.00.003-C03

 

=========================================

V1.00.003-C03, 2017 Mar 21 Released

1.Tamper more check and user confirm, since Tamper Enable behavior ONLY has ONE Chance

2.Remove Tamper Enable in RTC/Date & Time Set

3.Remove 09-14 in AR Platform in Connection


=========================================

V1.00.003-C02, 2017 Feb 23 Released

1.Eng Mode - Add Enter Bootloader Mode.


2.[Time Check]Remove Tamper Enable Cmd

before Time Check Cmds Performing, in Time Check Item.


3.[LCD Pixels] Combined 3 kinds of LCD Test Sub Items into one.

Each display has 800 ms interval time to next one.

Old: ON, Click [PASS] --> OFF, Click [PASS] --> Color Bars, Click [PASS]

New: ON->OFF->Color Bars->Again (10 secs period) , Click [PASS]


4.[Ethernet] Set After Test.

Old: Ethernet MAC Injection --> Ethernet Ping Check

New: Ethernet Ping Check --> Ethernet MAC Injection


5.[Start All Test][Run As Administrator]

Add 1st round notification regarding "Run As Administrator".


6.[Keypad test] - Add Cust Disp ON --> OFF to avoid Keypad no response problem.

FW:23558

V1.00.003-C01


1.RTC Timer Set / Get = 25-05 / 25-06

2.Add Ethernet MAC Address Injection / Check Item

3.[UI,Form04] Adjust Test Item Buttons Maxtrix Area sizing to all buttons view range.

4.Keypad Test Item Update

SW = r23240

SQA = ?

V 1.00.002




V1.00.002-C03

Internal Test


V1.00.002-C03, 2016 Dec 14 Released

1.Add "Administrator Privilege" in manifest.xml definition.


V1.00.002-C02

Internal Test


V1.00.002-C02, 2016 Dec 13 Released

1.Modified LED Display Message


V1.00.002-C01

Internal Test


V1.00.002-C01, 2016 Dec 08 Released

--< Mod >--

1.Network Ethernet Interface Setting Cmd D1-13 Tx/Rx Format Updated

2.[Eng Mode], Some Test Buttons are not cleared after disconnection.

3.KeyPad Test - Cancel Function Ready but still takes time to end (1~4 secs).

Timeout Value Per Pressing Delay , 50 secs --> 4 secs.

4.Formal Part Number Added

+IDPP – 138


*V1.00.001-C03, HWOnly


2016 Nov 08

V1.00.001-C03

HW Test Tool


V 1.00.001




*V 1.00.001-C03

Formal Release


V1.00.001-C03

Formal Release for ..

1.Board Level Test

2.Production Test

3.QC Mode Test


V1.00.001-C01


V1.00.001-C01

PISCES, Beta 1 Version


V 0.00.0XX




V 0.00.006-C01


TS158, V0.00.006-C01

PISCES, Beta 1 Version


SetupTS158_0.00.005-C10.exe


V0.00.005-C10, 2016 Sept 07 Released

1.Mod - Tamper Test, Replace messages "Can't Get Tamper Status" with "Get Tampers Done with OK, All OFF"

2.Mod - USB Connection, Make MSR Test Duration from 2.2s downto 0.3s response time.


SetupTS158_0.00.005-C09.exe


V0.00.005-C09 Released, Sept 06

1.Tamper Test Forever Loop Bugs

2.Tamper Value Display


SetupTS158_0.00.005-C08.exe


V0.00.005-C08 Released, Sept 05

1.Message Changed. Tamper 2,3 --> Wire 0,1


SetupTS158_0.00.005-C07.exe


V0.00.005-C07 Released, Sept 02

1.Modified Tamper Get Status Value.

2.De-activate RFID Interface After Poll For Token.


SetupTS158_0.00.005-C06.exe


V0.00.005-C06 Released

1.Touch - Signature Simplification
2. RS232 connection - Reader Detection Failed Problem


SetupTS158_0.00.005-C04.exe


---<005-C04>---

SetupTS158_0.00.005-C02.exe


---<005-C02>---

SetupTS158_0.00.005.exe


---<005-C01>---

SetupTS158_0.00.004.exe


---<C004>---

SetupTS158_0.00.003.exe


---<C003>---

SetupTS158_0.00.002.exe


---<C002>---

SetupTS158_0.00.001.exe


---<C001>---


  • No labels