001 - TS188, VP5300 M, K81+Sanwa Sub-board Motor Controller
Deprecated Note:
This TS has been migrated to Universal TS project and been deprecated from now on.
Universal TS Link: 900 - Universal TS . TW
Please be advised.
Ref Pages
/wiki/spaces/PMH/pages/71447461
02.VP5300M sub-board download tool
03.Sankyo-Subboard Programmer Guides
Test Instruction
Version | Comment |
---|---|
80171001-TI_Rev B.docx | Support new type-b card(80005222-001) |
80171001-TI_Rev A.docx | Revision 57 → Revision A |
80171001-TI_Rev 57.pdf | Add Type A and Type B card test |
80171001-TI_Rev 56.pdf | Add instructions of set device configuration separately |
80171001-TI_Rev 55 | Merge instructions of sub-board simulator, mainboard test |
Unit test(Production & QC) Board level test(Mainboard & Ethernet) | 1. Add QC test |
80171001-TI_Rev 53 | 1. Detect and check speed and sensor voltage automatically(min,max) |
V1.0.0.4 |
|
V1.0.0.3 | 1.Show the summary of Sanwa motor sensors |
TS Download Link
Version | Date | Comment / Jira Tickets / Bitbucket Hash | Approved |
---|---|---|---|
V 1.0.2.4 | TE-994 | ||
|
- Speed Value Validation Range Update - Yano-san's Recommendation : (300-15)ms ~ (300+15)ms (Min,Max) Old - 298~311 New - 285~315 - Effective Model Number Scope - IDM-001, Production + QC - IDM-001D, Production + QC - IDM-101D, Production + QC - IDM-181, Production + QC - IDM-181D , Production + QC - New Value Validation Information Display for Ex: "Acquire card transport speed:0309[mm/s], (Min,Max) = (285,315)" Where "(Min,Max) = (285,315)" is the notification of valid range. | ||
V 1.0.2.3 | TE-946, -C02 TE-972, -C03 | ||
| 1.[Tamper Check Item] Tamper Log Event Removed. - Effective Part Number Scope: * IDM-001D, QC mode * IDM-101D, QC mode * IDM-181, QC mode * IDM-181D, QC mode | ||
| |||
|
Correct Response: 56 69 56 4F 74 65 63 68 32 00 81 00 00 0C 01 0A 60 59 06 D0 16 80 C5 80 00 01 8A 00, <-- the last byte is 00.
Ex01: ------[Notes For Test Script Developer]------- | ||
V 1.0.2.2 | TE-820 | ||
|
目前有個漏洞..1st Unit 如果沒有 DEK, 2nd Unit 有, 2nd one 一樣會 pass , Version Scope:from V1.0.2.2-C01 | ||
| @goofy
==[Known Issue]== 1.目前有個漏洞..1st Unit 如果沒有 DEK, 2nd Unit 有, 2nd one 一樣會 pass , Version Scope:from V1.0.2.2-C01 | ||
V 1.0.2.1 | |||
| 1.Fixed RS232 Test : Connection Issue Relative XML Files: Interface.xml 1.b [Potential Issue] ----------------------------------------- 2.All Test Items. Relative XML Files: Production.xml; QA_TW.xml; ----------------------------------------- ----------------------------------------- 4.[RFID Test] Card Removal Waiting Time Fine-Tune Relative XML Files: Production.xml; QA_TW.xml; | ||
V1.0.1.7 | |||
| 1.Fixed RS232 Test : Connection Issue 2.Removed ALL Reboot Counter Set/Check Items+Commands. | ||
-C04.zip |
| 1.[Production Mode] End Secure Task must running to prevent DUT from passthrough on/off hazard. Relative Part Numbers: IDM-001 IDM-001D IDM-101D IDM-181 IDM-181D | |
-C03.zip |
| 1.LEDs+Buzzer Test @ QC Mode +Removal 90-07 Start Secure Task Command. It caused the PT-ON & PT-OFF command failed (0x2B) and useless in Activated and Ready Modes Relative Part Numbers: IDM-001 IDM-001D IDM-101D IDM-181 IDM-181D
2.Fixed [Setting Item] @ QA mode No Work Issue when 1st startup TS. Developer Note tag: "2020 Dec 31" | |
-C02.zip |
| 1.Fixed [Log] Folder Issue 2.CL Test invalid TQM description | |
-C01.zip |
| 1.Test Item Rename 2.Fixed Dual MSR Setting Issue | |
V1.0.1.6 | 1.Add IDM-001D and IDM-181 SHA512: c033c5feaebdee9ee6c41b0274d30d8da8d67a46b28efe684894870e260536ad814d9c4f7cfca0631aa163790b92bc4d7e6397791816e2c6862f79e049a6e89d | ||
V1.0.1.5 | 1.Fix SAM card test issue of board level test SHA512: c62db82a3cc2be582d4a34c5a9005f10dbd75b2adf8bbe9ef6dd383d72ecb4bd5e119810bb92a652018578ddce993b30568f13545ed8c171fd652c7337b947e3 | ||
V1.0.1.4 | 1.Check new format C7 3D command SHA512: 99b3e82d7ee5c9d1fb3f1ec2aa51aa198bec01409c08017ffb06f7d4642abed7cc89fe8844d8dd547ff9919a1c47d710caccdd2e4f943f9845174f0ef7e62e3b | ||
V1.0.1.3 | 1.Add stop cursor when single step mode is inactivate SHA512: 93e8b2f9da941e68c2f07c422e3012574ab9e10f45dddfdf35c4dd0b8d0ebc661b90ce1a0429661e3e8562a2b3946715a000698db8f3451d0ea04fe9d349dd06 | ||
V1.0.1.2 | 1.Change default COM port from COM4 to COM1 SHA512: f1ef0f2f54374de05702f7ac40e3b441e06a7c70ab0b47a920362297b7abb61ed3c08bbb2e1daeb7b28ab919942e564ef2d6bd3fe10bc3f353805c3dd337d247 | ||
V1.0.1.1 | 1.Change ethernet LED check method of 80171323-001, IDM-181D SHA512: 32854e9e08d366261d9e7c6f1359cefc10b3ab05849ec0541209e4c34ac111764cc1f127395c2dbc31d307fac82b587bcacd56e29c90b2938641b245cc78bcf3 | ||
V1.0.1.0 | 1.Fix duplicate test result issue SHA512:f036639ae633238ba861ec7c9fb5b9d06a83cf203d8675c8fdf2cb7d707e4114279ec98144ea25a41e5bb7cdb6343f0f790df78bd12fce51c2449da6e3a999f9 | ||
V1.0.0.9 | 1.Add certificates and key info into test result report SHA512:f564b58ce714dd930ef6fa07d8b8185feac770750819c5826bcbc3c04411e3d81063a95df77ec6b4f304d1948729f676a3e611031a1a34ab0d77996440d8404a | ||
V1.0.0.8 | 1.Add function to check boot up times SHA512:918f2a3e4d02dc694ae387370bc712a5499c647c7a0ffef91fdf856fb03d44d431045438e279e5a6631d7422a3d6a89a120730bc784e860eb819ef9f9fe108a9 | ||
V1.0.0.7For Sanwa | 1.Voltage standard reminder For Sanwa SHA512:2096489217b70f3ec41f645b370e02f5249216d5e9f16ad1bc1a929e613da48c9bdd2ccfc669a304114ef5fa9c4e2dbafa5e0e4e473d8a95961a3bb4bdc73891 | ||
V1.0.0.6For YangMei For Sanwa | 1.Add MSR setting test For YangMei SHA512:a3438d9902fe225916f5e72569c71cbf6628a4363045e2f6e9a72263275cbe821c69303ebe1311b0bf615ca2b82a0af20efc6853055452eebea4dc4051119f45 For Sanwa SHA512:7009ccc2c918096064504a3bdd69b4beadf7620a4f5321d8fb96ff8377aff762e6820dbb216b2b9a3ab52d55ed7adf8fdd67e5210714494811dc53601cb87248 | ||
V1.0.0.5 | 1.Clear response and result before test SHA512:d8ae96b2caeff0298a2065f1a697ae86203425bf95b9d2fc18841ecf45fa622f21bdba78a941c7b5cca7b2adbc4be6de58a3a157dcb12bbc831c028db23c86a0 | ||
V1.0.0.4 | 1.Fix Sanwa sensor result display error SHA512:f591678e7fdb9f14b6895deaa023fb3374a642136a511f71e0acfb4cd8a660033d2fdbf6bce5027ec78884774f78c30084885822b8eb4d9fa760d7d8ddbe2955 | ||
V 1.00.001 | |||
old: 緩慢小心放入磁條卡片 new: 緩慢放入晶片卡直到被自動收入
80171xxx, Key: LCL-KEK; PCI Pairing, for FW Product Version 80171xxxD, Key: LCL-KEK; DUKPT; PCI Pairing, for FW Demo Version | |||
80171xxx-PD, Key: LCL-KEK; DUKPT; PCI Pairing 80171xxx-D, Key: LCL-KEK; PCI Pairing
|
Test Tool for EE / ME / FW
Version | Date | Comment | Approved |
---|---|---|---|
V 1.0.2.1.ICC.MeTool | |||
| 1.P/N List Updated [+] 01_EngMode-ICC_CPU_Memory, For ME ICC (CPU+Memory) Test. Note: DUT must be Ready Mode (Certificates + Keys Installed) ICC Memory Card : SLE 4442; SLE 4428 |
Stress Test Tool | ||
Version | Comment | Approved |
---|---|---|
V 1.00.004 | ||
1.Add cmd line "VP5300M_STM" param for VP5300 stress test purpose. ---<Developer Note, 2C-72, Verification AutoP+Burst Response (Logs) from VP5300M>-- "TEST:000001_ICC:OK" => _ICC:OK => TEST:ICC:OK +1 "ICC:POWER_ON_Fail" => "ICC:POWER_DOWN_Fail" "SUB:Entry_FAIL:" + sanwan response "SUB:Eject_Error:" + sanwan response "SUB:Cancel_Error:" + sanwan response A : Communication Interface, RS232 okay but USB-HID not verified yet. B: Start => 2C-01 PT ON => 2C-71, Motor Mode ON => 2C-72, Verification ON => Waiting Rx Stop => 2C-73, Cancel /Stop => 2C-01 PT OFF C: Key Item Logs Display. = times be found Ex: TEST_ICC:OK = 5 => 5 times PASSED in ICC TEST. |
Sanwa Sub-board Simulator
Version | Comment | |
---|---|---|
Simulator Sanwa_Subboard_Simulator_V1.0.0.0.zip Test instruction | A tool to simulate the behavior of Sanwa sub-board and motor used in board level test SHA512:76fcf8c086a63f191a823bad395ea9a3f6dfc723cd9a90e8c1e714bcc8ad42408ab7d917754ba8a140a1b6846619edff062e360e29264539da551520e6fd4015 | |