901 - Wiki : QC Mode to check Json file, NEO1 TS Only !!



#1 Building Steps

Steps

Content/Description

Note

Steps

Content/Description

Note

A. Before Starting…

  • TS160, V2.04.003-C01

  • ViVOConfig MFG Tool, V1.0.2.102

  • IDT VP3300 USB Reader

 

  • Installation

  • 1.ViVOConfig MFG Tool, for Production Line. from Arena

https://app.bom.com/items/detail-spec?item_id=1306217844&version_id=12113350458

  1.2. Json File Location for ViVOConfig MFG tool. (Should be its default path)

\\192.168.1.162\Manufacture\ViVOconfig.MFG

  • 2.TS160 DL Link, Confluence Page.

 

 

B.Setup “IDT VP3300 USB Reader” to meet requirement.

Here is an example for this step

  • IDT Reader VP3300 USB.-Ex.A

  • Json: CFG-SHIFC01-06-2.json-Ex.B

  • UpdateIDT of TS160-Ex.C,


Steps

#1.Inject LCL-KEK by using TS, Passed TM/Production mode Done.

#2.Inject Product DEK by HSM, TG3 Room. Or Inject Demo DEK by TS/RKIPKI System.

#3.Inject Json, using ViVOConfig.

 

C. Inject Json File

#1.Using ViVOConfig MFG Tool, Mode = Production Mode, to Load Json File.

Json Example = Ex.B

*Note: Using UNI default path to retrieve specific json file.

#2. Using this MFG Tool QC Mode to check Json-In Reader Configuration Result after Passed or Warning Message are found.

Save Log Result as Tool.QC.Result.Log.A

Note. If there is/are errors , please make sure the solid compability between

IDT Reader (EE Configuration, A/B/C) + Firmware Version + Json Configuration.

 

D. Create UpdateIDT QC Mode Log File.

 

Fig A

 


#1. put B into C’s sub folder “UpdateIDT\Configuration, see U2 of Fig B.

#2. Edit Json-Verifying Purpose Batch File, i.e. VP3300USB_Test_ViVOConfig_Verify-USBHID.bat, See Fig A Right Side.

Give correct json file name in the content of the batch file. See U5 of Fig B. Here is CFG-SHIFC01-06-2.json.

#3. Execute the batch file, U5.

#4. Get Log File from U3, Rename it to ext log file , CFG-SHIFC01-06-2_Verify_Std.log. as - U6

 

Fig B

 

Q:UpdateIDT.exe command line arguments.

A:See

E. Put json file + Verify_Std.log into TS sub folder

  • Here is the Part(Model) Number Example = ID-80149009-001

  • Put both files into the subfolder,i.e. PartNumber\ ID-80149009-001\QC\CFG

See Fig A Left Side

 

 

F. Run TS’s QC Mode and Final Check Result of Correctness in Json settings.

  • Run QC Mode Passed and Until End Processing w/ Json Check (if TS found Json & Log File' dual-existance)

Note. TS gets UpdateIDT QC Mode Result TS.QC.Result.Log.A, compare it with CFG-SHIFC01-06-2_Verify_Std.log w/o error/fail Keywords = passed. I.E. TS.QC.Result.Log.A = CFG-SHIFC01-06-2_Verify_Std.log

  • Run ViVOConfig MFG QC Mode to check the DUT again and get log Tool.QC.Result.Log.B.

  • =====

Compare Tool.QC.Result.Log.A = Tool.QC.Result.Log.B w/o difference and Done !!