Objective:


TargetComment

1.Loop Test

Allow User to customize test item run loop test counter.

2.Continue Test After Error 

Enable = If test step failed, Tool keeps going to next test step w/o stop.

Disable = stop test step if any error, or timeout.




User Guide:

VersionDateComment

Errata 2021.11.22

 

  • Objective:To preventing from DQA Test Tamper Mechanism OFF problem.

-Isolated Tamper Activation : _TamperSet at Model Number Selection,

-Isolated Set Time+Device Reset  : _TimeSet_And_DevReset at Model Number Selection.

  • DQA Tool Version: V3.2.5.001-C01 or later
  • Support Projects:

  White Sand / Olympic / Bryce Canyon

  • Tamper Activation Instruction / UI:

V1.00

 

003 - TS196, VP3350, Joshua Tree#003TS196,VP3350,JoshuaTree-UserGuide-Simple


Download List - NEO3x - VP8810; VP8810P; VP6825;

VersionDate / Git-HashComment

 


goofy.liu

DQA Test Tool. V3.2.5.001-C01.DQA.AIO,

  • Objective: 修正 Device Reset 導致 Tamper Function Disable 的問題.
  • 1. Update Items Order
    Objective:
    - SetTime Item contains Device Reset (90-00) Command.
    - Device Reset (90-00) Command disables the Tamper Enable Function (90-02).
    ==> 90-00 must be prior to 90-02 command.
    Old Test Items precedence of partial Model Numbers :
    Tamper Enable --> SetTime
    New :
    Tamper Enable. Removed SetTime Item from Normal Model Number.
    Production Run Mode 目前只會 GetDRS讀取 Tamper 狀態.


  • 2. PartNumber (P/N) List Updated

2.1 + _TimeSet_And_DevReset = ONLY for Timer Set And Device Reset.
Project Selection Scope: VP8810/VP6825/VP8810P

利用此Model Number 項目設定時間日期. 與 Device Reset.

2.2 + _TamperSet = ONLY for Tamper Activation and Check,

  利用此 Model Number 項目設定 Tamper Activation, 與進行檢查, 必須選擇 VP6825 產品進入.
TprSet_Oly : VP6825 , Tamper Activation
TprChk_Oly : Tamper Check
TprSet_WSand : VP8810 , Tamper Activation
TprChk_WSand : Tamper Check
TprSet_BRC : VP8810P, Tamper Activation
TprChk_BRC : Tamper Check
Project Selection Scope: VP6825

** Note: Please see the Errata V2021.11.22

 

goofy.liu

V3.2.4.001-C07.1.DQA.AIO,

  • 1. Tamper Check Item Updated

 - Removed All Device Reset 90-02 Behaviors

 - Effected Project Scope.

   VP8810 / VP6825 / VP8810P

  • 2.Light Sensor Min Value Updated

old: 2040

new: 1536

 - Effected Project Scope.

   VP6825

 

goofy.liu

 ALL In ONE, for DQA

  • 1.IDTechCommDll_CSharp Project.
     - Adding unbufferSize_Tx; unbufferSize_Rx; as buffer size definition.
     native: 4096 bytes
     new: 16384 bytes
     enhancement root-cause : 90-02 tampered response sometimes might be 
  • 2. All Production Mode Updates for DQA Test
    TestItems: +RS232; +Ethernet,
    Products: VP8810/VP6825/VP8810P
  • 3.Update LTE Network Ping Destination URL.
    old: ping www.google.com
    new: ping www.baidu.com.cn

 

goofy.liu

DQA.AllInOne,

  • 1.Update Light Sensor Test Script: Check Range Value.

old : <CheckMethod minValue="2040" maxValue="3050"

new : <CheckMethod minValue="2040" maxValue="4095"


 

goofy.liu

  • 1.Full Support Models
    VP8810 / VP6825 / VP8810P
  • 2.Support LTE 4G Network Ping Test.
    Slot: SIM1, Must install registed 4G network SIM Card.
    Dest Website: www.baidu.com.cn.
    Certificate Mode OFF --> Ping Test --> Certificate Mode ON




Download Link, DQA Reliability Test Tool, Loop Test Tool

VersionDateComment

 

 goofy.liu

  • 1.NEO3 Device Supported HID's PID List.

VP8810 = 4680
VP6825 = 4670
BryceCanyon = VP8810P = 4680 (Might be updated to new in near future)

VP8810-Tamper = Tamper Test ONLY, VP8810
VP6825-Tamper = Tamper Test ONLY, VP6825
BryaceCanyon-Tamper = Tamper Test ONLY, BryceCanyon

Exe file="NEO3x_DQA_LoopTestTool.exe"

------------------

  • Known Issue:

1.Tampered Status Table Issue.

Tampered points found but wrong color indicator.




  • No labels