Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Import Macro Repair

Before Starting: Talk to your salesperson about creating a sales order for remote key injection. They will provide you with more details, but the sales order should contain the serial number ranges, as well as the key part number you want to inject. 

...

  1. Open the uDemo
  2. Connect your reader you want to key inject
  3. In the commands menu navigate to "Device" -> "execute RKI" and click on "execute RKI"
  4. Press "Execute Command" 
    1. Image RemovedImage Added

Note: RKI will take a few seconds to complete. The uDemo will appear to be doing nothing. Please Don't panic, close the uDemo, nor unplug the reader until you see something in the "Results" window. 

...

Double check your KSN. If you happen to be trying out RKI for demo purposes, ensure that your key looks like:

629949FF00000000

Note the 0xFF after the first 3 bytes. This is due to the Augusta only accepting a Rev.B key block.


 

 

Filter by label (Content by label)
showLabelsfalse
spacesKB
showSpacefalse
sortmodified
titleRelated articles
cqllabel = "kb-article" and label = "rki" and space = "KB"
labelskb-solution topic

...