When you burn new K81 Firmware can use the Docklight script to load Project DT to Device.
PS. Device Tree is only supported after FW version 1.00.072T.
Step-by-step guide
- Download Release Firmware
VP6825 Firmware Release - TWRD - IDTECH - Confluence (idtechproducts.com) - burning the k81 firmware by jlink
Image location: K81\Manufacture
jlink tools setting please reference
Neo 3 VP3350 Programing Instruction - Information sharing - IDTECH - Confluence (idtechproducts.com) - Execute Docklight to load the Project DT
Image location: K81\Source\PTP
VP6825_DT_PRJ_A_V1_demo : For 3 SAM (LTE)
VP6825_DT_PRJ_B_V1_demo : For 4 SAM (NO-LTE)
Modify the HID number to Olympic Device
1. double click to setting HID number
2. Choose the current HID number
0xACD:4670 for Olympic.
Confirm Device Connection is successful.
1. Confirm HID number
2. Confirm communication connection successful.
3. Execute the command table from 0 to 21 on the left side.
4. Confirm IDF command get response 90 - 00
ㄎ - Reboot device.