This section explains how to create and modify application identifiers (AIDs) and associate them with TLV Groups in the reader's memory for specific types of transaction handling. Detailed descriptions of the configurable application identifier (CONAID) commands are also included.
Each AID uniquely identifies a payment application. The reader has default AIDs that are preconfigured to support common payment applications. These AIDs are called System AIDs and they can be modified or disabled, but not deleted. Readers also support up to eight user-defined AIDs called User AIDs.
Each AID must be associated with a TLV Group that defines transaction processing for that payment application. The System AIDs are initially associated with a default TLV Group (called Group 0), which can be modified but not deleted. User AIDs can be associated with the default TLV Group or any of seven other user-defined TLV Groups.
With the implementation of M/Chip 3.0, an additional default TLV Group (Group 80 for NEO II or Group 1 for NEO product) has been added. M/Chip 3.0 does not use the Reader Default Group (Group 0).
All AIDs must be unique. The reader's default configuration is based on System AIDs and two default groups. All of the System AIDs (except PayPass AIDs, ) as noted above ) initially refer to the default TLV Group 0. The diagram below shows the default reader AID configuration.

The configurable application identifiers feature of the ViVOpay readers allows users to create and customize AIDs and the TLV Groups associated with them. Each AID may have characteristics that are unique and different from the reader's default System AIDs and TLV Group configuration.
To create a new configurable AID, send to the reader both:

...


If the AID already exists in the reader's memory, it will modify the AID accordingly. When sent a new AID, the reader creates and saves the new AID. Multiple AIDs can be associated with the same TLV Group, or they can map to unique TLV Groups. Users may also redefine the functionality for an existing AID by linking it to a new configuration Group, or they may disable an AID if to prevent the reader from processing transactions from that payment application. Users may delete an AID by communicating to the reader the AID number with no parameters.
As users add or modify AIDs and TLV Groups, the reader remembers all changes on subsequent boot upbootup.
The diagram below shows an example of a reader's AID configuration after it has been modified with Configurable AIDs.


In the above example:

  • Ten System AIDs have been disabled and four User AIDs and three new TLV Groups have been configured.
  • The new AID User AID – 1 has been linked to the Reader Default Configuration (TLV Group 0) so that it functions as the other System AID 1 functions.
  • The Maestro AID has been linked to the user-defined TLV Group – 2.
  • User AID – 2 functions as defined in the new TLV Group – 3.
  • Both User AID – 3 and User AID – 4 point to the new TLV Group – 4 and function accordingly.

Also, notice that the other System AIDs have been disabled by removing their link links to a configuration group.
Use the configurable AID commands to create new AIDs or change configuration values for an AID. Use the Configurable Group commands to create new groups or configuration values for a group.

...

Byte 0-9

Byte 10

Byte 11

Byte 12

Byte 13

Byte 14

Byte 15

Header Tag & Protocol Version

Command

Status Code

Data Length (MSB)

Data Length (LSB)

CRC (MSB)

CRC (LSB)

ViVOtech2\0

04h

See Status Code Table

00h

00h




The user may NOT delete a System AID. If this command is used on a System AID, the reader disables that System AID but does not delete it. That System AID can be restored at any point by using the Set AID command on it. Until that point, it does not function but continues to reside in the reader's database.
When deleting an AID, the reader returns an OK response for successful operations. If it failed to find a matching AID, it returns 60h (data does not exist).