Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info
titleQuick Facts:
  • PCI 4.x certified PIN Entry Device

  • outdoor unattended

  • supports TDES encryption algorithm using DUKPT and Master/Session key
    management

View file
nameSmartPIN L100 datasheetSmartPINL100_Datasheet_v11.23.pdf
pageDownloads - Home
height400250
Live Search
spaceKeyKB
sizelarge
placeholderSearch for SmartPIN L100 related content here
typepage
labelsl100

...

Expand


...

Hide if
special@anonymous

Internal only: This is only visible if you are logged in to confluence 

  1 Use "78 31" cmd to get FW version
  2 Units with FW V1.00.xxx - V1.02.xxx can not be upgraded in the field to the V1.03.xxx which supports PKI-RKI as their bootloaders are not compatible due to cert loading/activation process/key injection procedures are different between PKI-RKI and the traditional (RSA key) Symmetric RKI … thus we can not use bootloader utility to upgrade FW from V1.00~V1.02.xxx to V1.03.xxx. but after V1.03.xxx, the bootloader utility can be used to upgrade FW in the field. (per Jenny Zhou 11/16/20)
  3 if customer use the L100 with fw 1.01 or 1.02 well, they do not need to send unit back for fw upgrading because there is no cert expiration issue. Only the L100 with 1.03 need to update the certification before cert. expired. (TS-29778)
  4 RS-232 - USB cable part # 81060228-001, D89 to USB cable: there are two part numbers for USB interface, and no 5 V power cable needed:  80141217-001 or 81060229-001 Rev.B, (see TS-25294)
  5 Blinking yellow LED means no key; Blinking green LED means the key's injected and new passwords are set after the pressure points are depressed, but the Removal Detection haven't been activated; Solid green indicating the Removal Detection is activated and the unit is ready to work. If fail to actaivate with the LED stays blinking green, send the "78 52 01 51" for L100 or  "75 46 52" command to get and clear the removal detection log 1st and then activate the Removal Detection again using the user passwords, it should work.  The pressure points must be depressed firmly in order for the user passwords can be accepted during the activation process (See Cubic's TS-27486)
  6 PCI 4.x extended from April 30, 2023 to April 30, 2024

Kevin Vo added a comment - 07/Mar/19 3:02 PM -This is the latest L100 firmware.L100_App_V1.02.009.S.fm

Use 78 31 to get FW version


All attachments labeled l100