Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Image Modified



Table of Contents


Test Instruction - TI, 80158217

VerDateComment

Rev D



80158217-TI-Rev D_VP8300_20230516.docx


 

1.       Update the path for the TQM log file.

Register:[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\IDTech_TS]

Value:C:\TS_Log

New: TQM Log file path:

[IDTech_TS ]\TS1XX\(Product Name)\(TSVersion)\SN_PASS_DateTime.log

2.       ICC Test Card Replacement. (80005217-001 Rev. A)

 

  • 1.Update ICC Test Card.

Old: Type 01 + Type 02, 2 kinds of cards

New: New ICC Test Card, 1 kind ONLY.

  • 2.Adding Summary Log – QC mode
  • 3.Removed P/N List Information.

goofy.liu

 

TQM Test Request Support.

  • 1.A RFID : 0cm+4cm
  • 1.B ICC Contact Test:

      Type 01 + 02 Contact Card Combination Test.

  • 2.Revised Pages

Page 3,8, and 10.

goofy.liu

 

  goofy.liu

Initial Version



Visa-TQM Audit Notes:

Test ItemComment

RFID

1.Contactless Card Type : A (a.k.a. Mifare) + B

TypeComment

A

A.K.A. Mifare Card

B


2.Range Criteria : 0 cm + 4 cm / per card

ICC Smart Card

  1. Get ATR

  2. APDU Operation: Open + Read Data from the Smart Test Card.



Download Link


Ui expand
expandedtrue
titleDownload


VerDate / Git-HashCommentApproved by

V 1.01.008


Jira Legacy
serverSystem Jira
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keyTE-2587

-C03.zip

 See ReleaseNote.txt in detail

V 1.01.007


Jira Legacy
serverSystem JIRA
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keyTE-2123

-C02.zip

 See ReleaseNote.txt in detail

V 1.01.006


Jira Legacy
serverSystem JIRA
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keyTE-1643

-C02.zip

 

See ReleaseNote.txt in detail

1. Due to the bug in "TS166", the update will be performed synchronously.


V 1.01.005


TE-1586

-C03.zip

 

Shawn.Huang

See ReleaseNote.txt in detail

Add "8300 USB" product name.

Mindy Yang  
Test report: /wiki/spaces/EN/pages/67281934

-C02.zip

 

Shawn.Huang

1. RFID test add "remove card" step after Type B finish.


-C01.zip

2023年05月02日

Shawn.Huang

See ReleaseNote.txt in detail

1. KSN Value Issue (SWT-826)

2. APDU command step update  (SWT-833)

3. Summary log update (SWT-840)

4. Ignored TLVs update

5. TQM Log file path update

6. Add an "x" before each folder name of the PartNumbers have been OBS.


V 1.01.004


TE-1421

SWT-754


 

goofy.liu 

1.P/N List Updted

 + IDV8-300APD     AES, MSR/MSD ON,   EMV ON,     LCL-KEK+DEK(Demo)


V 1.01.003


TE-1229

SWT-587


 

goofy.liu 

1. Fixed ICC Test Unstable Issue in QC mode.

   Solution: Added Ping Check after system rebooting and re-connection.


 

goofy.liu 

1. Fixed duplicated json file verification steps.
Removed extra verification step.

2.RFID updated, 
Turn off the buzzer during the test.


 

goofy.liu 

1.IDV8-300P2-P1 Updated
  + 24743-rev8.json loading & verification.

    
2.TimeChk Update, 
    - QC Mode ONLY
    
    - Ask User to allow the Time Diff Value more than tolerance.
       - Select 'Yes', 1 time only and keep ignoring the error, but have logged info.
       - Select 'No', 1 time only and acts as normal error process.
       
    -Effected Model Numbers.
     ALL Model Numbers
    
3.[UI]Rename Form04 Window's Top Tool Bar label.
  Production --> Production; Sum Log
  QC-Mode --> QC-Mode; Sum Log
  
  *Mouse RightButton-Clicking on this lable to open summary log file updated after all test items done.
  
4. QC Mode "FWInfo" Item
  Ignored spec multiple TLVs during tags verification.
  -9F41 Transaction Counter.
  -9F21 Transaction Time.
  -9A   Transaction Date.
  -DFEE3A USBInterface HID/KB Indicator.
  
5.Enhanced ICC Test 
  ICC Card - 80005221-001, current
           - 80005217-001 Rev. A, VP5300M , dual MSRs and ICC


V 1.01.002




 

goofy.liu 

Updated External Cmd Tool "UpdatedIDT.exe"

      - External Tool Updated: Updated IDT, Rollback to old one.

         Version : 1.0.1.30 (Oct 10 2021 Updated) --> 1.0.1.20

      - Effected Model Number

        - IDV8-300P-I1, CFG-IMPULSE-01.json,

        with Frmw;K21;W/BL;VP3300/VP8300;VP3300 USB NEO v1.01.184


 

goofy.liu 

  • 1. Model Number Updated List,      
        (+) Added IDV8-300P2-P1 
          - TDES, MSR/MSD ON, EMV ON, 
          - 2nd BT Chip, Vendor = Avnet.
          - Frmw;K21;W/BL;EMV2.6;VP3300 USB NEO v1.10.035

    (M) Updated External Cmd Tool "UpdatedIDT.exe"
      - External Tool Updated: Updated IDT
         Version : 1.0.1.20 --> 1.0.1.30 (Oct 10 2021 Updated)
      - Effected Model Number
        - IDV8-300P-I1, CFG-IMPULSE-01.json,
        with Frmw;K21;W/BL;VP3300/VP8300;VP3300 USB NEO v1.01.184
   

  •    2. New Test Item Added : Reset
       - Device Reset : Production Mode ONLY, 
       - IDG Command: Reset to Default(04-F0)

V 1.01.001


TE-991
24         New:    MSR/MSD/EMV OFF

 

goofy.liu

  • 1.Json File Injection Support.
      - P/N List
      - IDV8-300P-I1, CFG-IMPULSE-01.json
       Note 01 : Arena only contains ImpulsConfig.exe to loading the EMV L2 Configuration.

       - Production Mode , + Write+Check the json file.
       - QC Mode, + Check the reader's EMV L2 data , against the CFG-IMPULSE-01.json content.

        Native: MSR/MSD/EMV ON

(CFG File : 59036063)

 1.1 Removed P/Ns List

  - IDV8-300, OBS

  - IDV8-300A, OBS

  - IDV8-300D, OBS

  - IDV8-300PD2, OBS

     - IDV8-307, Unreleased, Removed.

       - EMV L2 Encryption Mode, (No Change)

            MSR/MSD = ON

            EMV = ON

  • 2. Log Files Path update

Objective: execute TS in the remote site (LAN Server , UNC path, ex: \\mfg-fileserver\UTS\VP8300\TS177.exe)

Old: \\mfg-fileserver\UTS\VP8300\Logs

New: \\mfg-fileserver\UTS\VP8300\Logs\LocalPCName_EthMAC_112233445566,

          where Local PC's MAC Addr = 112233445566


Image Added



  • Json file export tool : ViVOConfig Configuration Utility.
  • How to Gen CFG-IMPULSE-01.json file.
        step 01 - Reset VP8300 Device, Cmd=04-F0, 
                  w/ Firmware "VP3300 USB NEO v1.01.184"
        step 02 - Run ImpluseConfig.exe,which is downloaded from Arena "IDV8-300P-I1's CFG-IMPULSE-01 item"
        step 03 - Use ViVOConfig Utility V1.0.001.093 version "Read Config From Device", save the data as
                  "CFG-IMPULSE-01.json" file.

V 1.00.009


Jira Legacy
server

ID TECH -

System JIRA
columnIdsissuekey,summary,issuetype,created,updated,duedate,assignee,reporter,priority,status,resolution
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keyTE-765


 

goofy.liu

  • 1.Fixed can't perform ICC Test Issue.

 

goofy.liu

  • 1.P/N List Updted

 + IDV8-300P2D     TDES, MSR/MSD ON,  EMV ON,  LCL-KEK+DEK(Demo)

 + IDV8-300AP2D     AES, MSR/MSD ON,   EMV ON,  LCL-KEK+DEK(Demo)


V 1.00.008




 

goofy.liu

  • 1.Visa-TQM Audit Issue - RFID Test Updated 
    old : 0cm+4cm && CL Type A ,   2-subTest required.
    new : 0cm+4cm && CL Type A+B , 4-subTest required.

SQA Test JIRA :

Jira Legacy
server

ID TECH -

System JIRA
columnIdsissuekey,summary,issuetype,created,updated,duedate,assignee,reporter,priority,status,resolution
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keyTE-438


V 1.00.007




 

goofy.liu

  • 1.P/N List Updated
    [+]IDV8-300PD2, TDES, MSR/MSD ON, EMV ON, LCL-KEK+DEK(Demo)
    [+]IDV8-300P2, TDES, MSR/MSD ON, EMV ON, LCL-KEK
    [+]IDV8-300AP2, AES, MSR/MSD ON, EMV ON, LCL-KEK
  • 2.Adding Summary Log.txt after Production/QC mode test.
    opening summary.log
    Clicking [Production / QC mode] at the top status bar of the test items running window.

Ex: Summary-2020616-IDV8-300PD2_QC.log

Image Removed

Image Added

  • 3.[ICC] New ICC Test Card.
    old: Type 01 + Type 02
    new: New ICC Test Card.

Image Modified

Mindy Yang  

RE TS177VP8300 V1.00.007-C01 Released V02.msg

V 1.00.006




 

goofy.liu

  • 1.P/N List Updated

[+] IDV8-300P-I1, TDES, MSR/MSD ON, EMV ON

Mindy Yang  

RE VP8300TS177 V1.00.006-C01 Released.msg

V1.00.005




 

goofy.liu

  • 1.P/N List Updated

[+] IDV8-307, TDES, MSR/MSD ON, EMV OFF

USB-KB, ICS = 5C, Set Terminal Data(5C)

Kate Hung  

RE TS177VP8300 V1.00.005-C01 Released.msg

V 1.00.004




 

goofy.liu

  • 1.Fixed Demo P/N Issues
    1.a updated key injection content
    old: DUKPT Admin Key (LCL-KEK) - Production Version
    Key Name - IDT-KEYINJ-A107
    DUKPT Admin Key (DEK) - N/A
    Key Name - N/A

    new: DUKPT Admin Key (LCL-KEK) - Demo Version
    Key Name - IDT-KEYINJ-DR0002
    DUKPT Admin Key (DEK) - Demo Version
    Key Name - IDT-KEYINJ-D01
    1.b P/N List , w/ Demo DUKPT Initial Keys(LCL-KEK + DEK)
    IDV8-300PD, TDES, MSR/MSD ON, EMV ON
    IDV8-300D, TDES, MSR/MSD ON, EMV ON
  • 2.AdminKey_Injection.exe updated
    for Demo Key Injection Support.
    V1.1.0.8 --> V1.1.0.9

V 1.00.003




 

goofy.liu

  • 1.TQM Request Supported

1.A RFID Test : 0cm+4cm

1.B ICC Test :

  old: Insert Contact Type 02 Card --> Remove Type 02 Card --> Done

  new: Insert Contact Type 01 Card --> Remove Type 01 Card --> Insert Contact Type 02 Card Insert --> Remove Type 02 Card --> Done

  • 2.FW Information Update.

old: VP3300 USB-BL-V3.00.012

new: BL Version = VP3300 USB-BL-V3.00.012

  • 3.More Checks in TS Version String.

Mindy Yang  

RE VP8300TS177 V1.00.003-C01 Released.msg

V 1.00.002


--< P/N List >--

  • IDV8-300,         TDES, MSR/MSD ON,  EMV OFF
  • IDV8-300N,        TDES, MSR/MSD OFF, EMV OFF
  • IDV8-300A,        AES,  MSR/MSD ON,  EMV OFF
  • IDV8-300P,        TDES, MSR/MSD ON,  EMV ON
  • IDV8-300AP,       AES, MSR/MSD ON,  EMV ON
  • IDV8-300P-C1,       TDES, MSR/MSD ON, EMV ON
  • IDV8-300D,          TDES, MSR/MSD ON, EMV OFF
  • IDV8-300PD,         TDES, MSR/MSD ON, EMV ON

 

 goofy.liu

  • 1.Fixed AdminKey Execution Files Missed Issue.

 

 goofy.liu

  • 1.PN List Updated

[+]IDV8-300P-C1, TDES, MSR/MSD ON, EMV ON

[+]IDV8-300D,    TDES, MSR/MSD ON, EMV OFF

[+]IDV8-300PD,   TDES, MSR/MSD ON, EMV ON

  • 2.Test Item(s) Improvement.

2.1 - RFID Test

  Old : Poll For Token (PFT(GetUID)) --> Antenna Power OFF (APOFF) --> Done.

  New : PFT(GetUID), 0 cm distance --> APOFF --> PFT(Card Removal,Please) -->

        APOFF --> PFT(GetUID), 4 cm distance --> APOFF --> Done.

2.2 - ICC Test , Up Timeout Value for 60-14 read card status period.

  • 3.Release File Format Changed.

old: installation exe type, user\data\AppRoam\TSXXX....

new: zip type, local folder.


V 1.00.001




 

 goofy.liu

1.new P/N

IDV8-300,  TDES, MSR/MSD ON, EMV OFF

IDV8-300N, TDES, MSR/MSD OFF, EMV OFF

IDV8-300A, AES, MSR/MSD ON, EMV OFF

IDV8-300P, TDES, MSR/MSD ON, EMV ON

IDV8-300AP, AES, MSR/MSD ON, EMV ON


2.Initial Version