2.TimeChk Update, - QC Mode ONLY - Ask User to allow the Time Diff Value more than tolerance. - Select 'Yes', 1 time only and keep ignoring the error, but have logged info. - Select 'No', 1 time only and acts as normal error process. -Effected Model Numbers. ALL Model Numbers 3.[UI]Rename Form04 Window's Top Tool Bar label. Production --> Production; Sum Log QC-Mode --> QC-Mode; Sum Log *Mouse RightButton-Clicking on this lable to open summary log file updated after all test items done. 4. QC Mode "FWInfo" Item Ignored spec multiple TLVs during tags verification. -9F41 Transaction Counter. -9F21 Transaction Time. -9A Transaction Date. -DFEE3A USBInterface HID/KB Indicator. 5.Enhanced ICC Test ICC Card - 80005221-001, current - 80005217-001 Rev. A, VP5300M , dual MSRs and ICC
How to Gen CFG-IMPULSE-01.json file. step 01 - Reset VP8300 Device, Cmd=04-F0, w/ Firmware "VP3300 USB NEO v1.01.184" step 02 - Run ImpluseConfig.exe,which is downloaded from Arena "IDV8-300P-I1's CFG-IMPULSE-01 item" step 03 - Use ViVOConfig Utility V1.0.001.093 version "Read Config From Device", save the data as "CFG-IMPULSE-01.json" file.
1.P/N List Updated [+]IDV8-300PD2, TDES, MSR/MSD ON, EMV ON, LCL-KEK+DEK(Demo) [+]IDV8-300P2, TDES, MSR/MSD ON, EMV ON, LCL-KEK [+]IDV8-300AP2, AES, MSR/MSD ON, EMV ON, LCL-KEK
2.Adding Summary Log.txt after Production/QC mode test. opening summary.log Clicking [Production / QC mode] at the top status bar of the test items running window.