- In uDemo, under the Device tab, select Send Data Command option in the commands list.
- In the dialog box, enter the following command to enter passthrough mode: 72 46 20 01 00 01 and select Execute Command.
The results window should display Send Command Response ASCII: ?'F ??. - To clear the L80's log files, enter the command 78 52 01 51 and select Execute Command.
The results window should display the response from the log file dump. If you receive a "Send Command Fail Error Code: 0x3: time out for task or CMD" response, make sure your L80 is powered on and awake.To exit pass-through mode on the Spectrum Pro, enter the command 72 46 20 01 00 00 and select Execute Command.