Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Download Release Firmware
    VP6825 Firmware Release - TWRD - IDTECH - Confluence (idtechproducts.com)
  2. burning the k81 firmware by jlink

    Image location :  K81\Manufacture



    jlink tools setting please  reference
    Neo 3 VP3350 Programing Instruction - Information sharing - IDTECH - Confluence (idtechproducts.com)

  3. Execute Docklight to load the Project DT

    Image location :  K81\Source\PTP

    VP6825_DT_PRJ_A_V1_demo : For SAM3
    VP6825_DT_PRJ_B_V1_demo : For SAM4


    Modify the HID number to Olympic Device

    1. double click to setting HID number
    2. Chocse the current HID number
            0xACD:4670 for Olympic.




    Confirm Device Connection is successful.

    1. Confirm HID number 
    2. Confirm communucatioon connection successful.
    3. Execute command table from 0 to 21 on left side.
    4. Confirm IDF command get response 90 - 00



  4. Reboot device.