June 07, 2016

NEO DL Manager

V1.00.002-C001

---------------------------

V 1.00.001-C001

Internal Test ONLY

NEO DL MGR V1.00.002001

----------------------

V1.00.001001

<V1.00.002-C001>

V1.00.002-C001

1.No Download Client Starts. Only 7/8 DL in progress.

Not A Bug. Please make sure that..

1.a) HID Device(s) is(are) ready in Device List of windows

If not fount in HID Device List, please change to another usb port and try again.

1.b) Make sure the reader has serial number.

Use TS to Input Serial Number after Test PASSED.

2.#1 Device can't download it in BL(bootloader mode).

2.a)Please usb J-Link to burn firmware image and try again

(remeber to input serial number).

2.b)Change another Unit and Try again.

3.NEO DL Client Crashed in 7th Reader USB Plug-in status.

Fixed Bug.While dumping error Tx Block, the text buffer

is overflowed.

=========================================

<V1.00.001-C001>

Target Platform: NEO + K21

1.Products : Vendi, (Unipay III, Unipay 1.5)

2.Concurrent Quantity : 1~8 Units

3. Firmware Image Type Check are ready.

For Ex: Vend Txt Image can't be DL into Unipay III Reader.

Mar 10, 2016

V1.02.005

Formal Release

2016 Mar 18 SQA Verified.

Setup_NEODLApp

=========================================

V1.02.005

 

2016 Mar 02

----< Modification >----

1.Rename to "NEO_DL_App"

2.Reset to Default

 Old cmd : 04-F0 , Cleanup Flash except Serial Number

 New cmd : 04-0A, Cleanup Flash except Serial Number + Loaded Admin Key (Loaded by Test Software)

You need to update Firmware Version to ...

#ReaderFW Version or later
1VendiNEO v1.00.051
2Unipay IIINEO v1.01.014.00A
3Unipay 1.5NEO v1.02.004.00A
Dec 02, 2015

V1.02.004

Internal Test

SetupGenericDLApp

-------------<Modification>-------------

1.Add /chklegacy parameter = Application Checks Vendi Old BL (ver < BL V3.00) Reader.

Without /chklegacy, DL App Never checks Old BL version.

2.Add command retry mechanism to prevent from accident failed. 3 times.

3.Add Unipay 1.5 USB HID Support (PID = 0x3130)

Oct 16, 2015

V1.02.002

Formal Release

SetupVendiDLApp

-------------<Modification>-------------

1.Some times reboot and system up ready wait time is short.

Increase Wait System Up Until Ping Response during 10 seconds timeout.

Relative Reader(s): Unipay III.

Sept 17,2015

V1.02.001

Formal Release

SetupVendiDLApp

-------------<Modification>-------------

1.Add Unipay III USB-HID Supporting (PID=0x3520)

2.Reader Device Info Database Module, under Construction.

3.change "strncmp" --> "strnicmp"

to make string comparison is case-insenstive condition

while check input FW image file's main+ext string.

Aug 11,2015

V1.01.007

Formal Release

SetupVendiDLApp

-------------<Modification>-------------

1.Add supporting Unipay III Dummy Garbage Data Handling

For Example:

2015/8/10 13:23:25.845 [TX] - 56 69 56 4F 74 65 63 68 32 00 18 01 00 00 B3 CD

2015/8/10 13:23:25.901 [RX] -

55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 66 56 69 56 4F 74 65 63 68 32 00 18 00 00 00 FA 83

Garbage = "55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 66"

 

2.[UI]

Progress Bar Enhancement (Using WinXP/Vista/Win7 Theme)

 

-------------<Fixed Bugs>---------------

1.Modified Error Log Display

First time App Starting up and connection @ USB Interface,

cancel the file opening then it shows "Open RS232 Interface failed"

 

2.RS232 Recv Procedure Bugs.

While garbage filtering process, the read data process failed

if 1st time read data length < 10 bytes.

Resolution: if (1st time read data len < 10) then retry read process.

 

3.

Jira Legacy
serverJira
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keySV-4

Vendi-DL_App V1.01.006 Downlaod AP will be terminated when previous download procedure is interrupted In Progress

Ans: Please checkout JIRA 's comment. Fixed in V1.01.007

Aug 05, 2015

V1.01.006

Formal Release
SetupVendiDLApp

-------------<Modification>-------------

1.Some Log Messages.

 

-------------<Bug Fixed>-------------

Jira Legacy
serverJira
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keySV-2

 

-------------<Not-Fixed Bugs>-------------

Jira Legacy
serverJira
serverId5c72af4b-e2b8-3562-b028-6bcef8f5fab0
keySV-3

 

Aug 04, 2015

V1.01.005

Release for Test

SetupVendiDLApp

[Modified]

1.Add IDG Recv Frame Check during RS232 / USB-HID Receiving Procedure.

 

2.Add COM Port Selection Mode + COM Port List Refresh.

 

3.Finetune Delay Time while Tx / Rx Data

 

July 22, 2015

V1.01.004

Formal Release

SetupVendiDLApp

 

 

[Modified]

1. File Format Acceptable status.

InterfaceAcceptable text script type
USB

XXX_RS232.txt

XXX_USBHID.txt
RS232XXX_RS232.txt

This version Uses ONLY ONE text script for both RS232

and USBHID interfaces for simplification purpose.

 

2.Select RS232 Interface,then Select XXX_USBHID.txt

Result  : Not Being Allowed to download the text script.

 

3.ONLY one text script type (RS232 type) is required.

USBHID text script type is removed in order to

simplify images management.

 

4.Downloadable File Check Rules

BL VersionDescription

Before

Vendi-BL-v3.00.001

Check ItemRule
1.File TypeMUST be Binary (*.bin)
2.Allowed Size280K~350K

From

Vendi-BL-v3.00.001

Check Item

Rule

1.File TypeMUST be Text (*.txt)
2.Text Content 1

One of the following content checks

Pos @ FileEqu String ValueValid Type
0 = Begin"#RS232 version"RS232
0 = Begin"#USBHID version"USB-HID
3.Text Content 2

One of the following content checks

Pos @ FileEqual String ValueValid
EOF string"END>"Yes
EOF String"END>\r\n"Yes
July 17, 2015

V1.01.003

SetupVendiDLApp

V1.01.003

2015 July 17 Release

[Added]

1.Add Reset to Default Command (04-F0)

This is strongly recommended to perform this

after FW download has done.

 

[Code Arch Modified]

1.USB-HID Interface Communication Architecture

July 14, 2015

V1.01.001-r0001

Vendi Download AP

This is new download application for Vendi

(New & Old Boot loader compatible)