Tool# | File Name | Description | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Download AP
User Guide:
| Release: SetupVendiDLApp_x.yy.zzz.exe Ex: SetupVendiDLApp_1.01.004.exe
Run Exe: "Vendi Download AP.exe" | Application Tool to download Text Script File into the reader for Bootloader (BL) / Firmware (FW) upgrade. Input: Text Script File
Note 1.Reader USB-HID Interface Checking PID,VID paired list
| ||||||||||||||||||
Old Download AP
User Guide:
| Release: Vendi Download AP_Vx.yy.exe Example: Vendi Download AP_V1.10.exe | Old Download Ap with Load Configuration Function. Note: ONLY for BL Version before Vendi-BL-v3.00.001 |
...
Date Posted | Version | Release package | Description and Release Note | ||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aug 12,2015 | V1.02.001-r001Internal Test ONLY | SetupVendiDLApp | -------------<Modification>------------- 1.Add Unipay3 Unipay III USB-HID Supporting (PID=0x3520) 2.Reader Device Info Database Module, under Construction.
XML file format as configuration of Reader Device Info File. Following Items for each reader device info 1) USB-HID VID+PID mapping, possible contains couple or more mapping list for one device. 2) RS232 Buadrate Default Value(BRDV) 2.1) FW mode BRDV = auto/9600/19200/... (list form, at least one setting) 3) Delay time settings for several time critical check points, such as Tx Rx ... 4) Others settings...
Multi-thread concurrent download function This will be implemented depending on Market/Sales/Customer requirement. We won't go through this now. Relative JIRA bug(s):
Plan this DL App to meet Generic Compatible Download abilities for near future | ||||||||||||||||||||||||||||||||||||||||||||
Aug 11,2015 | V1.01.007Formal Release | SetupVendiDLApp | -------------<Modification>------------- 1.Add supporting Unipay3 Unipay III Dummy Garbage Data Handling For Example: 2015/8/10 13:23:25.845 [TX] - 56 69 56 4F 74 65 63 68 32 00 18 01 00 00 B3 CD 2015/8/10 13:23:25.901 [RX] - 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 66 56 69 56 4F 74 65 63 68 32 00 18 00 00 00 FA 83 Garbage = "55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 66"
2.[UI] Progress Bar Enhancement (Using WinXP/Vista/Win7 Theme)
-------------<Fixed Bugs>--------------- 1.Modified Error Log Display First time App Starting up and connection @ USB Interface, cancel the file opening then it shows "Open RS232 Interface failed"
2.RS232 Recv Procedure Bugs. While garbage filtering process, the read data process failed if 1st time read data length < 10 bytes. Resolution: if (1st time read data len < 10) then retry read process.
3.
Vendi-DL_App V1.01.006 Downlaod AP will be terminated when previous download procedure is interrupted In Progress Ans: Please checkout JIRA 's comment. Fixed in V1.01.007 | ||||||||||||||||||||||||||||||||||||||||||||
Aug 05, 2015 | V1.01.006Formal Release | SetupVendiDLApp | -------------<Modification>------------- 1.Some Log Messages.
-------------<Bug Fixed>-------------
-------------<Not-Fixed Bugs>-------------
| ||||||||||||||||||||||||||||||||||||||||||||
Aug 04, 2015 | V1.01.005Release for Test | SetupVendiDLApp | [Modified] 1.Add IDG Recv Frame Check during RS232 / USB-HID Receiving Procedure.
2.Add COM Port Selection Mode + COM Port List Refresh.
3.Finetune Delay Time while Tx / Rx Data
| ||||||||||||||||||||||||||||||||||||||||||||
July 22, 2015 | V1.01.004Formal Release |
| [Modified] 1. File Format Acceptable status.
This version Uses ONLY ONE text script for both RS232 and USBHID interfaces for simplification purpose.
2.Select RS232 Interface,then Select XXX_USBHID.txt Result : Not Being Allowed to download the text script.
3.ONLY one text script type (RS232 type) is required. USBHID text script type is removed in order to simplify images management.
4.Downloadable File Check Rules
| ||||||||||||||||||||||||||||||||||||||||||||
July 17, 2015 | V1.01.003 | SetupVendiDLApp | V1.01.003 2015 July 17 Release [Added] 1.Add Reset to Default Command (04-F0) This is strongly recommended to perform this after FW download has done.
[Code Arch Modified] 1.USB-HID Interface Communication Architecture | ||||||||||||||||||||||||||||||||||||||||||||
July 14, 2015 | V1.01.001-r0001 | Vendi Download AP | This is new download application for Vendi (New & Old Boot loader compatible) |