1. Set Configuration Defaults and Keep Encryption Key Command (04-0A)
2. General Reset command (78 53 00)
3. Reset MSR only (73 53 00)
4. The "7F 53 00" will default all settings with the keys and transARM certificates all be removed
5. Start from V1.03.xxx FW, changing the reader from KBQC to USB-HID, the terminal config will be changed on the firmware level from "5C" to "2C" (CS-3606)
6. None of the reset commands (including the internal 7F 53 00) will affect the terminal config, terminal data, AIDs, and CAPKs on the EMV side. (TS-25648)
7. Get EMV L2 full kernel version (72 46 08 02)
8. Sales team confirmed that POS Portal would order a standard Augusta reader (PN: IDEM-251P) without configuration or key. They would be the ones doing config and key loading on their end for the reader to be Auth.net compatible. (TS-27834)
9. Use the "symmetric rev B PROD" option in uDemo to inject a production key to Augusta V1.03.019 FW unit
10. For a key injected Augusta which is based on TR31 KBH to set the encryption mode, to change from AED to TDES encryption, send the “78 4D 05 03 49 44 54 45 43 48 01“ in NGA and then re-inject the TDES key, then send “78 52 01 03“ in uDemo to confirm the encryption type is set to “00” (or TDES). See TS-29795
11. No ITP command to erase the setting of TransArmor TID under USB-KB mode. The T.ID can only be erased in HID mode via “78 53 00“ (NGA) command to reset the device. See TS-30684
12. PCI 4.x for Augusta S is extended from April 30, 2023, to April 30, 2024
13. If the firmware is V1.02.021 or above, use the “Symmetric RKI B-PROD”, any lower versions use the “Symmetric RKI A-PROD”. Same with the Demo units (but use the option ends with DEMO)
14. To get the KSN with the Augusta in HID mode, send "78 46 3E 05 00 02 02 00 00 00" with NGA wrap in uDemo. (Refer to Design spec for detail as the Augusta IDG doesn't contain the command data info)